Description
SIEMENS LTD.
TYPE: DF1151-EX PY
INFRARED FLAME DETECTOR
5357820001
EN54-10 CLASSES 1/2
0786-CPD-20496
DF1151-EX PY
PTB 02 ATEX 2159
EX IB IIC
T4 (-35°C ≤ TA ≤ 70°C)
CERBERUS
DFB1190
FLAME DETECTOR BASE
516536 02
COUNTRY OF ORIGIN: SWITZERLAND
The Siemens DF1151-EX (5357820001) is an infrared flame detector supplied with the DFB1190 flame detector base, forming part of a shipboard fire alarm system. It watches its protected area for flame and raises an alarm at the fire detection panel so the crew can respond. The detector carries EN54-10 classes 1/2 approval and the ATEX marking Ex ib IIC T4 for ambient temperatures from -35°C to 70°C, for use in areas with a hazardous atmosphere. It is offered in New Open Box condition.
Key Features
✓ Infrared flame detection, type DF1151-EX PY
✓ EN54-10 classes 1/2 approval
✓ ATEX certificate PTB 02 ATEX 2159, Ex ib IIC T4
✓ Ambient range -35°C to 70°C
✓ Supplied with DFB1190 flame detector base (516536 02)
Marine Applications
✓ Flame detection in engine rooms and purifier rooms
✓ Monitoring of fuel oil handling areas
✓ Pump room coverage on tankers within hazardous zones
✓ Paint stores and other flammable material stores
Technical Support
Prota Marine provides technical support, repair and onboard installation for the infrared flame detector and the wider fire alarm system. Our engineers assist with fault diagnosis on detectors, bases and detection loops, and support commissioning once the unit is fitted.