Description
FISHER CONTROLS
TYPE: 546
ELECTRO-PNEUMATIC TRANSDUCER
INPUT: 4 TO 20MA DC
OUTPUT: 6 TO 30
PRESS UNITS: PSI
AMBIENT TEMP.: -40 TO 140℉ (-40 TO 60℃)
67AF
AIR PRESSURE REGULATOR
SMC
MODEL: EAF3000
AIR FILTER
MAX.PRESS.: 9.9 KGF/CM2 150PSI
MAX TEMP.: 60℃(140℉)
The Fisher 546 is an electro-pneumatic transducer that converts a 4-20 mA DC control signal into a 6-30 psi pneumatic output within shipboard process control equipment. It comes as an assembly with a 67AF air pressure regulator and an SMC EAF3000 air filter, which handle the instrument air supply for the transducer. Rated ambient temperature is -40 to 60°C (-40 to 140°F), and the filter carries a maximum pressure of 150 psi (9.9 kgf/cm2). The assembly is offered in used condition.
Key Features
✓ Input 4 to 20 mA DC
✓ Output 6 to 30 psi
✓ Ambient temperature -40 to 60°C (-40 to 140°F)
✓ 67AF air pressure regulator included
✓ SMC EAF3000 air filter, 150 psi (9.9 kgf/cm2) maximum
Marine Applications
✓ Signal conversion for pneumatic control valves on boiler feedwater systems
✓ Steam pressure control loops on auxiliary boilers
✓ Fuel oil viscosity control valve actuation
✓ Cooling water temperature control valves
Technical Support
Prota Marine provides technical support, repair and onboard installation for the electro-pneumatic transducer and the wider marine control system. Fault diagnosis covers the signal input, the pneumatic output and the regulator and filter set, and commissioning support is available once the assembly is in place.