Description
ENDRESS+HAUSER
ORDER CODE EXT.: CM442-AAM1A2F010A
LIQUILINE TRANSMITTER
ORDER CODE: CM442-2EV0/0
FIRMWARE VERSION: 01.07.00 DEV.REV.: 1
MAINS: 100…230 V~ 50/60 HZ 55VA
INPUT DIGITAL: MEMOSENSE / FIXED CABLE SENSOR
OUTPUT ANALOG: 0/4…20MA / ACTIVE / ISOLATED
OUTPUT RELAY: ALARM RELAY / MAX. 253V~ / MAX. 0.5 A
WIRE COMMUNICATION: HART
PROTECTION CLASS: IP66/67 NEMA TYPE 4X
AMB. TEMP.: -20 < TA < +60°C
HUMIDITY: 10-95%, NON-CONDENSING
ASSEMBLED IN CHINA
The Endress+Hauser Liquiline CM442 transmitter, order code CM442-2EV0/0 with extended order code CM442-AAM1A2F010A, is a transmitter used in the marine control system. It takes digital input from a Memosense or fixed cable sensor. It passes that reading to the control system through an active, isolated 0/4-20 mA analogue output with HART communication. A built-in alarm relay is rated at max. 253 V AC and max. 0.5 A. The unit runs on 100-230 V AC, 50/60 Hz, 55 VA, carries IP66/67 and NEMA Type 4X protection, and has firmware version 01.07.00. It is supplied used.
Key Features
✓ Memosense digital or fixed cable sensor input
✓ Active, isolated 0/4-20 mA analogue output with HART
✓ Alarm relay, max. 253 V AC, max. 0.5 A
✓ 100-230 V AC, 50/60 Hz, 55 VA mains supply
✓ IP66/67 and NEMA Type 4X, -20 to +60°C ambient
Marine Applications
✓ Sensor signal transmission to engine room monitoring systems
✓ HART-enabled instrument loops in ship automation
✓ Alarm signalling from sensor points to the vessel alarm system
Technical Support
Prota Marine provides technical support, repair and onboard installation for the Liquiline transmitter and the wider marine control system. Our team handles fault diagnosis on sensor inputs, analogue outputs and the alarm relay, and provides commissioning support after installation.