Description
DAIICHI
TYPE: WTT2-92A-33
TRANSDUCER
INPUT: 460:115V 1200:5A
0~800 KW
115V 5A 50/60HZ
OUTPUT: DC 4~20 MA
The Daiichi WTT2-92A-33 is a transducer that turns an AC power measurement into a DC 4-20 mA output for the vessel’s control and monitoring equipment. It takes its voltage input through a 460:115V transformer ratio and its current input through a 1200:5A ratio, covering a span of 0-800 kW. The resulting analogue signal can be passed to switchboard instruments, alarm systems or power management controllers that act on generator or feeder load. Inputs are rated 115V 5A at 50/60Hz. This unit is offered in used condition.
Key Features
✓ Input ratios 460:115V and 1200:5A
✓ 0-800 kW measuring range
✓ Rated 115V 5A, 50/60Hz
✓ DC 4-20 mA output signal
✓ Type WTT2-92A-33
Marine Applications
✓ Generator load measurement on main switchboards
✓ Power signal input to power management systems
✓ Feeder load monitoring for alarm and monitoring systems
✓ Load signals for generator control panels
Technical Support
Prota Marine provides technical support, repair and onboard installation for the transducer and the wider marine control system. Our team helps with fault diagnosis where the 4-20 mA signal or the measured load looks wrong, and offers commissioning support when the unit is returned to service.