Description
DEIF A/S
TYPE: ADL-111Q96
INSULATION MONITOR FOR DC NETWORK
ORDER NO.: 100044782
ITEM: 2033100017
VARIANT: 2911750110.01
SUPPLY: 24V DC ±25% ≤ 4 W
MEASURING RANGE: 50..0KOHM
RELAY COUPLING: NORM. ENERGISED
MAX LEAK CAP.: 1μF
SCALE: 50..0KOHM
AUXILIARY VOLTAGE: 24VDC
PROTECTION: IP20. FRONT: IP52
The DEIF ADL-111Q96 (order no. 100044782) is an insulation monitor for DC networks, part of the vessel’s marine control system. It watches insulation resistance on a DC supply across a measuring range of 50 to 0 kOhm, with a normally energised relay coupling and a scale reading 50 to 0 kOhm. The unit runs from a 24 V DC supply (±25%, up to 4 W), accepts a maximum leakage capacitance of 1 μF, and is rated IP20 with an IP52 front. It is offered in new open box condition.
Key Features
✓ Insulation monitoring for DC networks
✓ Measuring range and scale 50 to 0 kOhm
✓ 24 V DC supply ±25%, up to 4 W
✓ Normally energised relay coupling
✓ IP20 housing, IP52 front, max leak capacitance 1 μF
Marine Applications
✓ 24 V DC distribution insulation monitoring
✓ Battery and emergency DC supply systems
✓ Switchboard insulation indication on DC circuits
Technical Support
Prota Marine provides technical support, repair and onboard installation for the DC insulation monitor and the wider marine control system. Our team handles fault diagnosis on the monitor and its DC network and gives commissioning support at the switchboard.