Description
HONEYWELL ANALYTICS ASIA PACIFIC CO.,LTD.
P/N: SPXCDALMTXF
SENSEPOINT XCD TRANSMITTER / SENSEPOINT XCD GAS DETECTOR
INSTALLATION DRAWING NO.: 3001G0471
TEMP.CODE: T4 32 VOLTS DC MAX, CLASS 2
PMAX=5.5W
TA:-40℃ TO +65℃
MADE IN KOREA
The Honeywell Sensepoint XCD (SPXCDALMTXF) is a gas detector transmitter for a vessel’s fixed gas detection installation. It works as the field unit that senses gas at its installed point and passes the reading back to the detection equipment, giving early warning of hazardous gas build-up. The unit is rated at 32 V DC maximum on a Class 2 supply, with a maximum power of 5.5 W, temperature code T4 and an ambient range of -40°C to +65°C. Installation follows drawing number 3001G0471. The transmitter is offered in New Open Box condition.
Key Features
✓ Temperature code T4
✓ 32 V DC maximum, Class 2 supply
✓ Maximum power 5.5 W
✓ Ambient temperature range -40°C to +65°C
✓ Installation drawing no. 3001G0471
Marine Applications
✓ Fixed gas monitoring in cargo pump rooms
✓ Gas detection in engine room and machinery spaces
✓ Hazardous area monitoring near cargo handling equipment
✓ Field detection point wired to a central gas alarm panel
Technical Support
Prota Marine provides technical support, repair and onboard installation for the gas detector transmitter and the wider gas detection system. Our engineers help with fault diagnosis on the transmitter and its connection to the detection equipment, and support commissioning once the unit is installed.