Description
CROWCON DETECTION INSTRUMENTS LTD.
QUAD CHANNEL MODULE SWITCH POSITION
DETECTOR TYPE:
SWITCH POSITION:
1: SOURCE
2: SINK (2 WIRE)
3: 0-5V
4: FIRE (CH1 ONLY)
BUS SELECTION:
SWITCH POSITION:
1: BUS1
2: BUS2
MODULE SELECTION:
SWITCH POSITION:
0: CHANNELS 1-4
1: CHANNELS 5-8
2: CHANNELS 9-12
LK1:- LINK IF BARRIER IS USED ON FIRE CHANNEL
The Crowcon Detection Instruments Ltd. Quad Channel Module, marked Switch Position, is a four-channel input module for the gas detection system. Its switches set the detector type as source, sink (2 wire), 0-5 V or fire, with fire available on channel 1 only. A bus switch assigns the module to Bus 1 or Bus 2, and a module selector places it on channels 1-4, 5-8 or 9-12. Link LK1 is made when a barrier is used on the fire channel. The module is in Used condition.
Key Features
✓ Detector type selection: source, sink (2 wire) or 0-5V
✓ Fire input option on channel 1 only
✓ Bus selection between BUS1 and BUS2
✓ Module selection for channels 1-4, 5-8 or 9-12
✓ LK1 link for a barrier on the fire channel
Marine Applications
✓ Multi-channel Crowcon gas detection control panels
✓ Expanding detector inputs in groups of four channels
✓ Combined gas and fire detector inputs in machinery spaces
✓ Fire detector channels routed through a barrier
Technical Support
Prota Marine provides technical support, repair and onboard installation for the quad channel module and the wider gas detection system. We assist with fault diagnosis on detector channels and bus settings, and with commissioning after the module is set up and installed.