Consilium Salwico SPK-2 Loop Processor Board – CS3000 Fire Alarm System

Consilium Salwico SPK-2 Loop Processor Board – CS3000 Fire Alarm System

Brand: Consilium
Condition: USED
Part Number: SPK-2 042101
SKU: PRTS065
Consilium

Description

CONSILIUM
SALWICO SPK-2
042101
LOOP PROCESSOR BOARD
SALWICO CS3000
SLE 9505004
R2A
SPSM-2 R5

The Consilium Salwico SPK-2 Loop Processor Board is a core electronic assembly within the Salwico CS3000 marine fire alarm system. Responsible for managing addressable loop communication between the main control panel and connected detectors, call points, and input/output devices, this board plays a critical role in ensuring reliable signal processing and fault detection across the fire detection loop. Its correct operation is essential to maintaining a fully functional, SOLAS-compliant fire alarm system onboard.

Key Features

✓ Functions as the primary loop processor, handling communication and data exchange between addressable fire detection devices and the CS3000 control panel.

✓ Compatible with the Salwico CS3000 fire alarm platform, referenced under part identifiers including SLE 9505004, revision R2A, and SPSM-2 R5 — subject to system configuration confirmation.

✓ Designed for installation within the fire alarm control cabinet; mounting location and environmental rating are typical of marine-grade panel-mounted electronics.

✓ Supports the integrity of addressable fire detection loops, enabling fault isolation and loop diagnostics as expected in SOLAS-regulated vessel fire safety systems.

✓ Replacement of this board should follow Consilium Salwico service procedures; compatibility with specific panel revisions should be confirmed against the vessel’s installed system documentation.

Marine Applications

✓ Installed in the fire alarm control stations of commercial vessels operating Salwico CS3000 addressable detection systems.

✓ Used across cargo vessels, tankers, bulk carriers, and passenger ships where Consilium Salwico fire alarm equipment is the approved system.

✓ Applicable to offshore platforms and FPSOs fitted with Salwico addressable fire & gas detection infrastructure.

✓ Relevant to naval auxiliaries, RoRo ferries, and cruise vessels where multi-loop fire detection systems require dedicated loop processing hardware.

✓ Utilised during scheduled maintenance overhauls, system upgrades, and corrective repairs to restore full loop functionality on Salwico CS3000 installations.

Why Marine Engineers Choose

Marine engineers and vessel operators specify the Salwico SPK-2 Loop Processor Board because it is the manufacturer-referenced component for maintaining the CS3000 system’s addressable loop performance — ensuring detection reliability, loop integrity, and continued compliance with fire safety requirements at sea.

Ideal For

Commercial cargo vessels, tankers, bulk carriers, passenger ferries, cruise ships, offshore platforms, and any vessel class operating Consilium Salwico CS3000 addressable fire alarm systems requiring loop processor repair or replacement.

Technical Support

Technical support is available for this part and the Salwico CS3000 fire alarm system, covering onboard installation guidance, board-level repair advice, and remote troubleshooting assistance. Enquiries regarding system compatibility and replacement procedures are welcome.

Request a Quote

Fill out the form below to get a customized quote for this product.


    Cost-Effective Solution
    We deliver high-quality spares that optimize your vessel’s performance without exceeding your budget.
    Expert Team
    Our experienced professionals bring unmatched expertise to every project, ensuring precision and reliability.
    Global Reach
    Based in Dubai and Singapore, we proudly serve clients across the globe with prompt and efficient services.
    Dedicated Support
    We’re here for you at every step, offering reliable assistance to keep your operations running smoothly.